| River 3 |
1 × XT60, 11–30V, 8A, 110W |
1 × 110W (or 2 × 45W in parallel) |
110W: 21.8V (about 24V cold) < 30V; 6.5A < 8A. Two 110W in series = 43.6V, over 30V. The 400W (48V) is over the limit. A 220W works but is capped at 110W. |
| River 3 Plus |
1 port, 220W, 13A, 11–50V (some sheets say 55V) |
1 × 220W, or 2 × 110W in series |
220W: 21.8V, 13A sits right at the 13A cap. 2 × 110W in series: 43.6V (about 48V cold) < 50V at 6.5A. The 400W’s 48V Voc rises to about 53V on a cold morning, which leaves no margin under 50V, so skip it. |
| River 2 Pro |
1 × XT60, 220W, 11–50V, 13A |
Same as River 3 Plus |
Same window and cap, so the same answer: one 220W, or two 110W in series. |
| Delta 2 / Delta 3 Classic |
1 port, 11–60V, 15A, 500W |
2 × 220W in series (440W), or 1 × 400W |
2 × 21.8V = 43.6V (about 48V cold) < 60V; 13A < 15A. Three 220W in series = 65.4V, over the limit. Two 220W in parallel = 26A, so the station caps the current at 15A. 400W: 48V (about 53V cold), 11A. Four 110W in a 2S2P layout: 43.6V, 13A, 440W. |
| Delta 3 Plus / Delta 2 Max |
2 ports, each 11–60V, 15A, 500W (1,000W total) |
2 × 220W in series on each port (880W), or 1 × 400W per port (800W) |
Each port follows the Delta 2 math. Two 400W in series on one port = 96V, so use one 400W per port. |
| Delta Pro 3 |
High-voltage: 30–150V, 15A, 1,600W. Low-voltage: 11–60V, 20A, 1,000W |
High-voltage: 6 × 220W in series (1,320W). Low-voltage: 2 × 220W in series (440W) or 1 × 400W |
6 × 21.8V = 130.8V (about 144V cold) < 150V; 7 × = 152.6V, over the limit. A single 21V panel is below the 30V minimum, so the high-voltage port needs at least two in series. 400W: 2 in series = 96V (800W); 3 = 144V, about 158V cold, too close to the limit. |