HP to Watts Calculator (and BTU to Watts)

The short answers

HP to watts
1 hp = 745.7 W (mechanical), 746 W (electrical), 735.5 W (metric). Watts = hp × 745.7 [1].
A motor uses more than its hp
Nameplate hp is shaft output. A 1/2 hp well pump motor (373 W at the shaft) draws 660–1,000 W, and its locked-rotor (starting) current is about 6× its running amps [3][4].
BTU to watts
Watts = BTU/h ÷ 3.412 for heat. For an air conditioner’s electricity use, divide by its EER instead. A 10,000 BTU window AC draws 800–1,000 W [2][12].

Jump to the calculator, the pump hp to watts table or the BTU to watts chart.

As an Amazon Associate, SolarGenAdvisor earns from qualifying purchases made through links on this page, at no additional cost to you.

HP to Watts Calculator

Box 1 converts units. Box 2 estimates what a motor actually draws from the outlet or battery. Box 3 converts BTU per hour, including an air conditioner’s input watts. Results update as you type. Before you change anything, each box shows a worked example.

1. Horsepower and watts 745.7 watts
1 hp × 745.6999 = 745.7 W (0.746 kW).
Electrical hp: 746 W. Metric hp: 735.5 W.

Factors from NIST SP 811 [1]. U.S. motor and pump plates use mechanical hp (the 550 ft·lbf/s horsepower). This is shaft power, not what the motor draws; use box 2 for that.

2. What a motor draws (input watts and amps) ~1,203 W input, ~7.8 A running
Shaft: 1 hp × 745.7 = 746 W. Input: 746 ÷ 0.62 = 1,203 W.
Amps: 1,203 ÷ (230 V × 0.67) = 7.8 A. Starting at 6×: about 47 A for a moment.

The defaults are Franklin Electric’s full-load efficiency (62%) and power factor (67%) for its 1 hp, 230 V, 2-wire well pump motor. For that motor, Franklin lists 1,215 W and 8.2 A at full load and 47.6 A locked rotor, about 5.8× [4]. Small single-phase motors often run at 55–65% efficiency. The amps or watts on your own motor plate beat any estimate.

3. BTU per hour and watts 2,931 W of heat
10,000 BTU/h ÷ 3.412 = 2,931 W, the heat-equivalent power.
An air conditioner rated 10,000 BTU/h at EER 11 draws about 909 W while its compressor runs (10,000 ÷ 11).

3.412 BTU/h per watt follows from EIA’s 3,412 Btu per kWh [2][1]. EER is BTU/h of cooling per watt of electricity [12]. Use the EER or CEER on the unit’s label; for the compressor-start surge, see the AC table.

Formulas: HP, Watts and BTU

The U.S. horsepower is 550 foot-pounds per second, and NIST’s conversion guide puts it at 745.6999 W. The same table lists the electrical horsepower at exactly 746 W and the metric horsepower (PS, CV) at 735.4988 W [1]. For everyday work, 745.7 and 746 give the same answer to three digits.

Watts = hp × 745.7  (kW = hp × 0.7457) hp = watts ÷ 745.7  (1 kW = 1.341 hp) Motor input watts = hp × 745.7 ÷ efficiency Motor amps = input watts ÷ (volts × power factor) Watts = BTU/h ÷ 3.412  (BTU/h = watts × 3.412) AC input watts = cooling BTU/h ÷ EER

The motor formula is the one the U.S. Department of Energy gives for input power at full rated load: horsepower × 0.7457 ÷ full-load efficiency, in kW [3]. Power factor is the ratio of real watts to volt-amperes [10]. That is why a motor’s amps come out higher than watts ÷ volts. Our watts to amps calculator covers that step, and the VA to watts guide explains why inverters and UPS units are rated both ways. For other conversions, see the power calculators hub.

HP to Watts Chart

Unit conversions only: this is shaft power, not what a motor of that size draws. Mechanical and metric columns use the NIST factors [1].

Horsepower from one quarter to 10 converted to watts and kilowatts, mechanical and metric
HP Watts (mechanical) kW Watts (metric hp)
1/4 hp 186.4 W 0.186 183.9 W
1/3 hp 248.6 W 0.249 245.2 W
1/2 hp 372.8 W 0.373 367.7 W
3/4 hp 559.3 W 0.559 551.6 W
1 hp 745.7 W 0.746 735.5 W
1.5 hp 1,118.5 W 1.119 1,103.2 W
2 hp 1,491.4 W 1.491 1,471 W
3 hp 2,237.1 W 2.237 2,206.5 W
5 hp 3,728.5 W 3.728 3,677.5 W
7.5 hp 5,592.7 W 5.593 5,516.2 W
10 hp 7,457 W 7.457 7,355 W

Watts to HP

Watts from 100 to 5,000 converted to mechanical horsepower
Watts HP (mechanical) HP (metric)
100 W 0.13 hp 0.14 hp
250 W 0.34 hp 0.34 hp
500 W 0.67 hp 0.68 hp
750 W 1.01 hp 1.02 hp
1,000 W 1.34 hp 1.36 hp
1,500 W 2.01 hp 2.04 hp
2,000 W 2.68 hp 2.72 hp
3,000 W 4.02 hp 4.08 hp
5,000 W 6.71 hp 6.8 hp

Motor HP Is Output, Not Input

This is where most hp-to-watts answers go wrong for backup power. DOE’s motor fact sheet says it directly: a motor of a given rated horsepower is expected to deliver that power in mechanical form at the motor shaft. What it draws from the supply is that figure divided by its efficiency [3]. Three things push the real numbers above hp × 746:

  • Efficiency. Small single-phase motors lose a lot of power as heat. Franklin Electric lists full-load efficiencies of 56% for its 1/2 hp 4-inch well pump motor, 60% at 3/4 hp and 62% at 1 hp. The 1/2 hp motor delivers 373 W at the shaft but draws 660 W at full load and up to 1,000 W at its maximum service-factor load [4].
  • Power factor. Franklin lists the same motor at 5.0 A at 230 V at full load, which is 1,150 VA for 660 W, and a full-load power factor of 64% [4][10]. Inverters and wiring have to carry the amps, not just the watts.
  • Starting current. A motor starting from standstill pulls its locked-rotor current until it gets up to speed. Franklin lists 28.5 A locked rotor for the 1/2 hp 230 V 2-wire motor, 5.7× its 5.0 A running current. At 1 hp it lists 47.6 A against 8.2 A, and at 1.5 hp 62.0 A against 10.3 A [4]. A 3-ton central AC compressor shows the same pattern: 87.4 A locked rotor against 14.1 A running [11]. Generator charts reduce this to a “starting watts” figure, and for pumps their running-plus-starting totals work out to about 2.5–3× running watts (our arithmetic) [8][9]. The current spike lasts only a moment, and the supply voltage sags during it.

The hp on the label doesn’t predict the amps

Sump pumps make the point. Wayne’s CDU-series pumps are all 120 V, and the 1/3, 1/2, 3/4 and 1 hp models are listed at 9.5, 10, 9.8 and 9.8 A: nearly the same current across a 3× spread in horsepower. Wayne’s EE-series pumps of the same horsepower are listed at 3.65–4 A [7]. Zoeller’s 3/10 hp M53, with a shaded-pole motor, is listed at 9.7 A at 115 V. Its 1/2 hp M98, with a permanent split capacitor motor, is listed at 9.4 A [5][6]. For sizing a battery or generator, read the amps or watts on the pump’s plate or cord tag and multiply by the voltage. Use horsepower only when that is all you have.

Pump HP to Running and Starting Watts

The planning ranges are the ones on our sump pump and well pump guides. They are set wide so that older and less efficient pumps fit. The maker columns show what specific motors are rated at. Franklin’s published figures for its current 4-inch well pump motors fall at or below the low end of our running ranges.

Pump motors from one third to 2 horsepower: shaft watts, running and starting watts planning ranges, maker figures, chart figures and Franklin minimum generator ratings
Pump Shaft watts Running watts (plan) Starting watts (plan) Maker figures Utility / retailer chart Franklin min. generator kW (2-wire / 3-wire)
1/3 hpOur sump guide 249 W 800–1,050 W 1,300–2,500 W Wayne CDU790: 9.5 A at 120 V; Zoeller M53 (3/10 HP): 9.7 A at 115 V [7][5] Sump 800 + 1,300 starting; well 1,000 + 2,000 [8] 2.25 / 1.5
1/2 hpOur sump, well guide 373 W 1,000–1,500 W 2,000–4,000 W Franklin 2-wire: 660 W full load, 1,000 W max, 5.0 A, locked rotor 28.5 A; Zoeller M98: 9.4 A at 115 V [4][6] Sump 1,050 + 2,200 (Lowe’s +2,150) [8][9] 3 / 2
3/4 hpOur sump, well guide 559 W 1,500–2,200 W 3,000–5,500 W Franklin 2-wire: 925 W full load, 1,350 W max, 6.8 A, locked rotor 36.9 A; Wayne CDU980E: 9.8 A at 120 V [4][7] — 4.5 / 3
1 hpOur well guide 746 W 2,000–3,000 W 4,000–7,000 W Franklin 2-wire: 1,215 W full load, 1,630 W max, 8.2 A, locked rotor 47.6 A [4] — 6 / 4
1.5 hpOur well (1.5–2 HP row) guide 1,119 W 3,000–5,000 W 6,000–10,000 W Franklin 2-wire: 1,690 W full load, 2,170 W max, 10.3 A, locked rotor 62.0 A [4] — 7.5 / 5
2 hpOur well (1.5–2 HP row) guide 1,491 W 3,000–5,000 W 6,000–10,000 W Franklin 3-wire: 1,985 W full load, 2,535 W max, 10.0 A, locked rotor 51.0 A [4] — — / 7.5

Shaft watts are hp × 745.7 (our arithmetic). Franklin figures are its 4-inch single-phase 230 V “G” motors: input watts at full load and at maximum service-factor load, full-load amps and locked-rotor amps. The 1.5 hp row uses the 2-wire motor and the 2 hp row the 3-wire motor; Franklin lists no 2-wire 2 hp. Franklin’s minimum generator ratings are for engine-driven generators [4]. Chart figures are running watts plus the additional starting watts the chart lists [8][9]. Our guides list 1.5 and 2 hp as one 1.5–2 hp row.

Voltage matters as much as watts. Most plug-in sump pumps are 120 V. Many deep-well submersible pumps are 240 V, and a 120 V-only power station can’t run one at any wattage; the well pump guide covers the 240 V options. If you are sizing a fuel generator instead, our 5,000 watt generator guide builds pump starts into whole-house load plans.

BTU to Watts (and AC Watts)

One kilowatt-hour equals 3,412 Btu [2], so one watt running for an hour is 3.412 Btu: watts = BTU/h ÷ 3.412. NIST gives the same factor, 0.2930711 W per BTU/h [1]. That is the right conversion for heat: a 1,500 W space heater puts out about 5,118 BTU/h.

BTU per hour converted to heat-equivalent watts and kilowatts
BTU/h Watts (heat) kW
1,000 293 W 0.29
5,000 1,465 W 1.47
6,000 1,758 W 1.76
8,000 2,345 W 2.34
10,000 2,931 W 2.93
12,0001 ton of cooling 3,517 W 3.52
18,000 5,275 W 5.28
24,000 7,034 W 7.03
36,0003 tons 10,551 W 10.55

An air conditioner uses far fewer watts than its BTU

An AC moves heat rather than making it, so its BTU rating is not its power draw. Its efficiency rating, EER, is BTU per hour of cooling per watt of electricity. That makes input watts = BTU/h ÷ EER: a 5,000 BTU/h unit at EER 8 draws 625 W [12]. LG’s 8,000 BTU LW8016ER lists EER 12.1 and 660 W, and 8,000 ÷ 12.1 = 661 W [14]. For 8,000–13,999 BTU room units, DOE’s federal buying guide lists CEER 10.9 for a less efficient model, 14.7 for ENERGY STAR and 15.4 for the best available [13]. The same logic applies to central air: 36,000 BTU/h is about 10,551 W of heat, but Goodman’s 3-ton unit lists 3,080 W at 95 °F [11].

Window air conditioner running and startup watts by BTU rating, compared with BTU divided by EER 12
Window AC Running watts Startup surge Check: BTU ÷ 12
5,000 BTU 400–550 W 1,000–1,600 W 417 W
6,000 BTU 450–650 W 1,100–2,000 W 500 W
8,000 BTU 600–800 W 1,500–2,400 W 667 W
10,000 BTU 800–1,000 W 2,000–3,000 W 833 W
12,000 BTU 900–1,200 W 2,300–3,600 W 1,000 W

Running and surge ranges are the window AC figures from our air conditioner on a solar generator guide: typical ranges for standard-compressor units, not exact specs. The last column is our arithmetic at EER 12. An inverter (variable-speed) AC ramps up gradually and avoids most of the startup spike.

Power Stations That Can Start a Pump

The check below holds each in-stock station we rate to the minimums our sump pump guide lists (surge rating, battery size and top running watts) and to the minimum generator output our well pump guide lists for 240 V pumps. Scores come from our scoring, which is synthesized from published specs, logged Amazon prices and Amazon customer reviews.

Which power stations meet our sump pump minimums at one third, one half and three quarter horsepower and our 240 volt well pump minimums, with price
Station Wh / output / surge 1/3 HP sump (120 V)1/2 HP sump (120 V)3/4 HP sump (120 V) 240 V well pump Price
EcoFlow TITAN 5000 5,017 Wh / 7,200 W / not listed Yes Yes Yes Up to 1 hp $3,199.00
EcoFlow DELTA Pro 3,600 Wh / 3,600 W / 7,200 W Yes Yes Yes No (120 V) $1,799.00
Jackery HomePower 3000 3,072 Wh / 3,600 W / 7,200 W Yes Yes Yes No (120 V) Check price at Amazon →
Jackery Explorer 2000 v2 2,042 Wh / 2,200 W / 4,400 W Yes Yes No No (120 V) $999.00

Our arithmetic against the guides’ thresholds. Sump minimums: 2,500 / 4,000 / 5,500 W surge and 1,500 / 2,000 / 3,000 Wh. Well minimums: 4,000 / 5,500 / 7,000 / 10,000 W for 1/2 / 3/4 / 1 / 1.5–2 hp. Where no surge figure is published (TITAN), we used the continuous rating. The HomePower 3000’s surge figure is listed with its 30 A outlet; see its card. Specs are from our product database, cross-checked against the sources listed.

240 V for well pumps

Most deep-well submersible pumps are 240 V. A 120 V power station can’t run one, whatever its watts.

240 V Home Battery for Well Pumps

EcoFlow TITAN 5000

EcoFlow TITAN 5000 · Our score 91/100

5,017 Wh · 7,200 W continuous · 120/240 V · LiFePO4 [21][22]

Price on Amazon: $3,199.00

A 240 V submersible well pump needs a 240 V source, and this is the in-stock battery we rate that has one: 7,200 W of 120/240 V split-phase output. That continuous rating alone covers the minimum generator output our well pump guide lists for pumps up to 1 HP (7,000 W). EcoFlow publishes no separate surge figure that we could find. Its 5,017 Wh battery gives about ~4.3 h of pump-running time for a 1/2 HP pump at 1,000 W, by our math. It expands in 5 kWh steps to 30 kWh.

Skip it if: You want something portable. TITAN is an installed battery that feeds your circuits through EcoFlow’s Smart Home Panel 10, which a licensed electrician installs. It is rated for dry indoor locations only (IP20).

120 V stations with 7,200 W surge

Big enough to start the 120 V sump pumps in our table up to 3/4 HP.

7,200 W Surge, Five 120 V Outlets

EcoFlow DELTA Pro

EcoFlow DELTA Pro · Our score 87/100

3,600 Wh · 3,600 W continuous · 7,200 W surge · 120 V · 99 lb · LiFePO4 [19][20]

Price on Amazon: $1,799.00

3,600 W continuous and 7,200 W surge on 120 V, which clears the starting figures our sump pump guide lists up to 3/4 HP (5,500 W). Its 3,600 Wh battery gives about ~2.9 h of pump-running time for a 1/2 HP sump pump at 1,050 W, by our math. A pump that cycles on and off in a storm lasts much longer than that.

Skip it if: You need 240 V. As sold, it is 120 V. Getting 240 V takes a second unit plus EcoFlow’s Double Voltage Hub, which one retailer lists as discontinued. It also weighs 99 lb.

7,200 W Surge on a 30 A Outlet

Jackery HomePower 3000

Jackery HomePower 3000 · Our score 87/100

3,072 Wh · 3,600 W continuous · 7,200 W surge · 120 V · 59.5 lb · LiFePO4 [17][18]

Check price at Amazon →

The same 7,200 W surge class with a smaller 3,072 Wh battery at 59.5 lb. The listings we checked put the full 3,600 W and the surge rating on its 30 A TT-30 outlet. Each 20 A household outlet is rated 2,400 W, which is still above the 1,500 W top running figure for a 1/2 HP sump pump. It supports a transfer switch for up to six circuits.

Skip it if: Your pump plugs into an ordinary outlet and needs a large start. No surge figure is published for the 20 A outlets, so check with Jackery before relying on one for a 3/4 HP pump. It is also 120 V only and cannot be expanded.

Mid-size 120 V station

Enough for a 1/3 or 1/2 HP plug-in sump pump.

For a 1/3–1/2 HP Sump Pump

Jackery Explorer 2000 v2

Jackery Explorer 2000 v2 · Our score 87/100

2,042 Wh · 2,200 W continuous · 4,400 W surge · 120 V · 39.5 lb · LiFePO4 [15][16]

Price on Amazon: $999.00

For the common 1/3 or 1/2 HP plug-in sump pump. Its 4,400 W surge and 2,042 Wh battery clear our sump guide’s 1/2 HP minimums (4,000 W surge, 2,000 Wh), and 2,200 W continuous covers the 1,500 W top running figure. It gives about ~1.7 h of pump-running time at 1,050 W, by our math, at 39.5 lb.

Skip it if: You have a 3/4 HP pump (our guide asks for 5,500 W of surge) or any 240 V well pump. It also takes only 400 W of solar.

Verdict: Multiply by 746, Then Add Losses

For a unit conversion, multiply hp by 745.7 (or 746) and divide BTU/h by 3.412. For a real motor, that gives only the shaft power. Divide by the motor’s efficiency for input watts, by volts × power factor for amps, and plan for a starting current around 6× the running current. A 1/2 hp pump motor is 373 W on paper, 660–1,000 W from the supply, and needs a 2,000–4,000 W start on our planning figures. To keep a 120 V sump pump running through an outage, the Jackery Explorer 2000 v2, currently $999.00 on Amazon, covers our sump guide’s 1/2 hp minimums. For up to 3/4 hp, the EcoFlow DELTA Pro (our score 87/100) has 7,200 W of surge. A 240 V well pump needs a 240 V source such as the EcoFlow TITAN 5000.

HP to Watts FAQ

How many watts are in 1 hp?

745.7 watts for the mechanical horsepower used on U.S. motors (NIST lists 745.6999 W). The electrical horsepower is exactly 746 W and the metric horsepower is 735.5 W. A 1 hp motor delivers that power at its shaft but draws more from the supply: Franklin Electric lists 1,215 W at full load for its 1 hp well pump motor.

How do I convert hp to watts?

Multiply horsepower by 745.7: 2 hp × 745.7 = 1,491 W, or about 1.5 kW. To go from watts to hp, divide by 745.7: 1,000 W is 1.34 hp. Use 735.5 instead if the rating is metric horsepower (PS or CV).

How many watts does a 1/2 hp pump use?

Its shaft output is 373 W, but it draws more. Franklin Electric lists 660 W at full load and up to 1,000 W at maximum service-factor load for its 1/2 hp 230 V well pump motor. Our sump and well pump guides plan for 1,000 to 1,500 W running and a 2,000 to 4,000 W start, which leaves room for older and less efficient pumps.

How many watts does a 1/3 hp sump pump use?

Plan for 800 to 1,050 W running and 1,300 to 2,500 W to start. EWEB's generator chart lists 800 W running plus 1,300 W starting. Wayne lists its 120 V 1/3 hp CDU790 at 9.5 A, about 1,140 VA, while its high-efficiency EE790 is listed at 3.65 A. Check the amps on your pump's cord tag.

Why does a motor draw more amps than hp × 746 ÷ volts?

Two reasons. Nameplate hp is output, and small motors are only about 55 to 65 percent efficient, so input watts are much higher. And motors have a power factor below 1, so the amps are higher again: amps = input watts ÷ (volts × power factor). Starting current is higher still, about 6 times running current on Franklin's locked-rotor figures.

How do I convert BTU to watts?

For heat, divide BTU per hour by 3.412: 5,000 BTU/h is about 1,465 W. That follows from 1 kWh = 3,412 Btu. For an air conditioner's electricity use, divide its cooling BTU/h by its EER or CEER instead, because an AC moves heat rather than making it.

How many watts does a 10,000 BTU air conditioner use?

A 10,000 BTU window unit typically draws 800 to 1,000 W running, with a 2,000 to 3,000 W startup surge on a standard compressor. At EER 12 the arithmetic gives 833 W. Its heat equivalent, 2,931 W, is not its power draw.

What is the difference between mechanical, electrical and metric horsepower?

Mechanical (imperial) horsepower is 550 foot-pounds per second, or 745.7 W. Electrical horsepower is defined as exactly 746 W. Metric horsepower (PS, CV, pk) is 735.5 W, about 1.4 percent smaller. U.S. pump and motor plates use the mechanical figure.

What size power station runs a 1/2 hp sump pump?

Our sump pump guide asks for at least a 4,000 W surge rating and 2,000 Wh of battery for a 1/2 hp pump. The Jackery Explorer 2000 v2 (4,400 W surge, 2,042 Wh) clears both. A 3/4 hp pump needs 5,500 W of surge, the class of the EcoFlow DELTA Pro. A 240 V well pump needs a 240 V source, not just more watts.

Sources

Conversion factors are from NIST and EIA. Motor figures are from DOE and maker documents (Franklin Electric, Zoeller, Wayne); several are retailer-hosted copies of maker documents, as noted. Pump and AC planning ranges are the ones on our own pump and AC guides, and station specs come from maker pages and retailer listings. Conversions, amps and runtimes are our arithmetic. Nothing here was measured by us. Last reviewed November 18, 2026.

  1. NIST Special Publication 811, Guide for the Use of the SI, Appendix B.9 (power): horsepower (550 ft·lbf/s) = 745.6999 W; horsepower (electric) = 746 W; horsepower (metric) = 735.4988 W; British thermal unit (IT) per hour = 0.2930711 W
  2. U.S. Energy Information Administration, British thermal units (Btu): 1 kilowatthour = 3,412 Btu; one Btu raises one pound of water by 1 °F
  3. U.S. Department of Energy, Motor Challenge fact sheet “Determining Electric Motor Load and Efficiency”: input power at full rated load = hp × 0.7457 ÷ full-load efficiency; a motor of a given rated horsepower is expected to deliver that power in mechanical form at the shaft; power factor drops as load falls
  4. Franklin Electric, AIM Manual, Submersible Systems, 60 Hz (2026 edition, Nebraska Dept. of Water, Energy and Environment copy): 4-inch single-phase motor specifications (“G” suffix) with full-load and maximum service-factor amps and watts, efficiency, power factor and locked-rotor amps; generator minimum ratings for 2-wire and 3-wire motors
  5. Zoeller, Model 53 / M53 catalog sheet (Cooney Brothers copy): 3/10 HP, 115 or 230 V, shaded-pole motor, 4.8–9.7 A
  6. Zoeller, Model 98 / M98 catalog sheet (Cooney Brothers copy): 1/2 HP, permanent split capacitor motor, M98 115 V 9.4 A, D98 230 V 4.7 A
  7. Wayne Water Systems, CDU-series submersible sump pump owner’s manual (Home Depot copy): 120 V, 60 Hz; 1/3 HP 9.5 A (CDU790, SPF33); 1/2 HP 10 A (CDU800); 3/4 HP 9.8 A (CDU980E); 1 HP 9.8 A (CDU1000); EE790 1/3 HP 3.65 A, EE800 1/2 HP 3.8 A, EE980 3/4 HP 4 A
  8. EWEB (Eugene Water & Electric Board), Generator Sizing Considerations: sump pump 1/3 HP 800 W running, +1,300 W starting; 1/2 HP 1,050 W, +2,200 W; well pump 1/3 HP 1,000 W, +2,000 W (as cited on our 5,000 W generator page)
  9. Lowe’s, Portable generator wattage worksheet (04/2017): 1/2 HP sump pump additional starting watts 2,150 (as cited on our 5,000 W generator page)
  10. Fluke, Power factor: what it is and how to calculate it: PF = real power (kW) ÷ apparent power (kVA)
  11. Goodman GSXN3 split-system air conditioner specification sheet: 3-ton compressor RLA 14.1 A, LRA 87.4 A, 208/230 V; 3,080 total watts at 95 °F outdoors (as cited on our 5,000 W generator page)
  12. Penn State, EGEE 102 Energy Conservation and Environmental Protection, 10.6 Air Conditioner Efficiency: EER = BTU per hour ÷ watts; a 5,000 BTU/h unit at EER 8 draws 625 W
  13. U.S. DOE Federal Energy Management Program, Purchasing energy-efficient room air conditioners: CEER 10.9 (less efficient), 14.7 (ENERGY STAR) and 15.4 (best available) for 8,000–13,999 Btu/h units
  14. LG LW8016ER spec sheet (8,000 BTU window AC): 660 W cooling, 6.2 A, EER 12.1 (as cited on our air conditioner wattage page)
  15. Jackery, Explorer 2000 v2 product page: 2,042 Wh LiFePO4, 2,200 W rated, 4,400 W surge peak, 120 V outlets
  16. Lowe’s, Jackery Explorer 2000 v2 listing: 2,042 Wh, 2,200 W / 4,400 W peak, 39.5 lb
  17. Off Grid Source, Jackery HomePower 3000 listing: 3,072 Wh LiFePO4, 3,600 W on the 30 A outlet, 20 A outlets 2,400 W each, 7,200 W surge, 120 V 60 Hz outlets, about 59.5 lb
  18. The Solar Lab, Jackery HomePower 3000 review: 3,072 Wh, 3,600 W continuous and 7,200 W surge on the 30 A RV outlet, 120 V only
  19. Camping World, EcoFlow DELTA Pro listing: 3,600 Wh, 3,600 W total AC output, 7,200 W surge, 99 lb
  20. Norwall PowerSystems, EcoFlow Double Voltage Hub listing: links two DELTA Pro units (3,600 W at 120 V each) for 240 V and 7,200 W; listed as discontinued
  21. pv magazine USA, EcoFlow launches 5–30 kWh residential storage system (Oct 14, 2026): TITAN 5000 7.2 kW at 120/240 V; IP20 indoor (as cited on our 5,000 W generator page)
  22. Backup Power Hub, EcoFlow TITAN review: 5,017.6 Wh, 7,200 W, 120/240 V; surge not listed; Smart Home Panel 10 installed by a licensed electrician (as cited on our 5,000 W generator page)

Need 7,200 W of surge for a bigger 120 V pump?

Check Price on Amazon →Save to cart
4,400 W surge for a sump pump ★
Shop on Amazon →

What to read next

Can a solar generator run a well pump? → Well pump watts by horsepower, the 240 V requirement and the batteries that can start one. What size do you need? → Add your appliances and get a capacity recommendation in a minute. Black Friday deal tracker → Today's Amazon prices on the models we track, through the Black Friday season.

Get our weekly power station research email

One product worth knowing about, one practical guide to sizing, solar setup, battery care or safety, and answers to reader questions, with sources cited. About two minutes a week; unsubscribe anytime.

Subscribe free on Substack → Opens Substack in a new tab. You sign up on Substack, which stores your address and sends the emails; we use the subscriber list only to send this newsletter. See our privacy policy.