ENERGY STAR + DOE Data · Updated November 2026
How Many Watts Does a Refrigerator Use? Running, Starting and kWh per Day
The short answers
- Average draw
- About 40–80 W for a new full-size fridge, or 1–2 kWh a day: ENERGY STAR medians run from 363 kWh a year for top-freezer models to 715 for French-door models with door ice [1].
- While the compressor runs
- About 80–200 W for a modern fridge; generic generator charts allow up to 400 W [7][10][11].
- Starting watts
- 1,200–2,200 W for a split second on generator makers’ charts. Inverter (variable-speed) fridges ramp up softly [10][11][16].
- Freezers and mini fridges
- Upright freezer about 50 W average, chest freezer about 25 W, mini fridge about 28 W [2][1].
Jump to watts by fridge type, starting watts or what size solar generator runs a fridge and freezer.
As an Amazon Associate, SolarGenAdvisor earns from qualifying purchases made through links on this page, at no additional cost to you.
Refrigerator Watts and kWh by Type
A fridge runs around the clock but its compressor cycles, so the useful numbers are its average watts and kWh per day. Every model sold in the U.S. is rated in kWh per year under DOE’s test procedure [4], and ENERGY STAR publishes those ratings for every certified model. We downloaded both of its lists on November 15, 2026, 4,942 refrigerators and 680 freezers, and took the median for each type [1][2]. Average watts are annual kWh ÷ 8,760 hours.
| Type | kWh / year (ENERGY STAR median) | Average watts | kWh / day | Most models fall between | At the federal maximum |
|---|---|---|---|---|---|
| Mini / compact fridge1,778 models · median 3.3 cu ft | 246 kWh | ~28 W | 0.67 | 206–332 kWh~24–38 W average | 289 kWh~33 W average |
| Top-freezer fridge840 models · median 18.0 cu ft | 363 kWh | ~41 W | 0.99 | 297–450 kWh~34–51 W average | 404 kWh~46 W average |
| Bottom-freezer / French-door, no door dispenser1,370 models · median 18.7 cu ft | 539 kWh | ~62 W | 1.48 | 397–630 kWh~45–72 W average | 599 kWh~68 W average |
| Side-by-side128 models · median 24.8 cu ft | 642 kWh | ~73 W | 1.76 | 495–762 kWh~57–87 W average | 696 kWh~79 W average |
| French-door with door ice & water336 models · median 26.6 cu ft | 715 kWh | ~82 W | 1.96 | 658–764 kWh~75–87 W average | 781 kWh~89 W average |
| Upright freezer510 models · median 15.5 cu ft | 438 kWh | ~50 W | 1.20 | 385–528 kWh~44–60 W average | 495 kWh~57 W average |
| Chest freezer (full-size)9 models · median 10.6 cu ft | 218 kWh | ~25 W | 0.60 | 201–346 kWh~23–39 W average; lowest–highest of all 9 models | 244 kWh~28 W average |
Our arithmetic on the ENERGY STAR datasets [1][2]. “Most models” is the 10th to 90th percentile; for chest freezers, only nine full-size models were certified, too few for percentiles, so their range is the lowest and highest of those nine, 201–346 kWh (9–22 cu ft). The last column is the median of the federal-standard kWh ENERGY STAR lists for the same models, roughly what a model that only just meets the federal limit would use. ENERGY STAR says certified fridges are about 9% more efficient than that minimum [3]. ENERGY STAR doesn’t list French-door as a separate type; those models sit in its bottom-freezer group, and we split that group on whether the door has an ice and water dispenser.
Why the bigger fridges use more
Size and layout both matter. The median top-freezer model in the list holds 18 cu ft and the median French-door model with door ice holds 26.6 cu ft, and ENERGY STAR notes that top-freezer models tend to use the least energy for their size [3]. DOE also rates models with through-the-door ice as a separate product class with a higher limit, which the federal-standard column reflects [1]. Older fridges use more than any of these: the federal-standard column is already about 10% above the ENERGY STAR median, and ENERGY STAR warns that fridges more than 15 years old cost noticeably more to run [3]. For an older fridge, read its label or measure it (both covered below).
Running Watts: What a Fridge Draws When the Compressor Is On
Few fridge makers publish running watts, but service data sheets do. One for current 18–20 cu ft automatic-defrost top-freezer models using R600a refrigerant lists 82–87 W running in a 70 °F room and 90 W at 90 °F, with the compressor running 24–30% of the time at 70 °F and 40–51% at 90 °F, plus a 178 W defrost heater [7]. That checks out against the label data: 90 W running 40–45% of the day is 0.86–0.97 kWh, close to the 0.99 kWh a day of the median ENERGY STAR top-freezer model (our arithmetic).
Generator makers’ planning charts run higher, because they have to cover every fridge. Honda lists an ENERGY STAR refrigerator or freezer at 132–192 W running [10]; Champion lists a generic refrigerator at 400 W [11]. Big French-door and side-by-side models sit toward the top of Honda’s range, and Champion’s figure is a safe allowance for an old or unknown fridge.
Run time isn’t fixed
How much of the day a compressor runs varies a lot by design and room. GE says modern compressors are designed to run 80–90% of the time and can approach 100% in hot, humid rooms [8]; Frigidaire says some of its French-door models have variable-speed compressors designed to run continuously except during defrost [9]. A fridge that runs most of the time is usually drawing less while it runs. That is why we don’t estimate energy from running watts × an assumed duty cycle; the kWh rating already captures it.
Defrost and the other loads
Frost-free fridges melt ice off the evaporator with an electric heater: 178 W in the service sheet above [7]. GE says the compressor stays off during defrost, which typically lasts about 35 minutes [8], so the heater and compressor don’t add together. Fans, lights and ice makers add smaller loads on top. All of it is included in the label kWh.
Starting Watts: Locked-Rotor Surge vs Running
A conventional compressor motor is switched straight on. For a fraction of a second, before it is up to speed, it draws its locked-rotor current, several times its running current. Embraco’s datasheet for a small 1/12 hp, 115 V fridge compressor shows the scale: 3.70 A locked-rotor against 0.55 A at full load, about 6.7× [12]. Whole-appliance figures are lower because the start is brief. The MicroFridge 3.1 cu ft fridge lists 4.5 A at start-up and 1.3 A operating at 115 V, about 520 and 150 VA [13].
For full-size fridges, generator makers publish planning figures: 1,200 W starting for an ENERGY STAR refrigerator or freezer (Honda) and 2,200 W for a generic refrigerator (Champion) [10][11]. These are allowances, not measurements of any one fridge. We use Champion’s 2,200 W in the station checks below because it is the safer of the two.
- One appliance: the station’s surge rating should clear 2,200 W.
- Fridge plus freezer: Champion’s rule is to add the highest single starting figure to the running watts of everything else [11], so 2,200 + 400 = 2,600 W. We also check the case where both compressors happen to start at the same moment, 4,400 W.
- Continuous output: easy. Even two fridges running at Champion’s 400 W each is 800 W.
Inverter (variable-speed) fridges start softly
An inverter fridge’s compressor is driven by electronics that start it at low speed and ramp it up over a few minutes. Embraco contrasts this with the “abrupt power loads” of on-off compressors [15], ACHR News says the soft start “dramatically reduces the starting current” [16], and Danfoss describes near-zero inrush [17]. If your fridge’s spec sheet says inverter or variable-speed compressor, start-up is rarely what limits a power station; battery size is. If it doesn’t say, assume a conventional start.
Mini Fridge, Freezer and Garage Fridge Watts
Mini fridge
The median certified compact fridge uses 246 kWh a year, about 28 W on average or 0.67 kWh a day [1]. Spec sheets for two 3.1 cu ft models list 1.0 and 1.3 A at 115 V, about 115–150 VA [14][13], and real running watts are a little lower than volts × amps for a motor. Two similar-size models can differ a lot: the MicroFridge lists 195 kWh a year and the Hisense LMT33M6AVE 321 kWh [13][14]. Our guide to how many watts a mini fridge uses breaks that median down by freezer compartment, defrost type and size, with amps, dorm limits and thermoelectric models.
Chest and upright freezers
Chest freezers are the efficient ones. The nine certified full-size chest models use 201–346 kWh a year (median 218, about 25 W), while the median upright uses 438 kWh, about 50 W, for a median 15.5 cu ft [2]. Almost all certified full-size uprights are frost-free (automatic defrost) [2], so like frost-free fridges they use a defrost heater. Honda gives freezers the same planning figures as fridges, 132–192 W running and 1,200 W starting [10]. Our solar generator for a freezer guide covers runtimes for freezers on their own, and our guide to how many watts a freezer uses breaks down chest, upright and compact freezers, their starting watts and garage use.
Garage fridge
ENERGY STAR’s figures assume an indoor room. In a hot garage the compressor runs longer: the service sheet above shows run time rising from 24–30% at 70 °F to 40–45% at 90 °F for the same 18 cu ft fridge [7], roughly 1.3–1.9× the compressor time (our arithmetic for that one model), and Frigidaire notes the same effect for garages in summer [9]. Cold is a different problem. Whirlpool says cold air can mask the need for cooling in a standard fridge, so its freezer can warm and thaw [19], and GE doesn’t recommend non-garage-ready models below 60 °F; its garage-ready models are rated for 38–110 °F [18]. For a second fridge in a garage, budget above its label kWh in summer.
How to Read the Yellow EnergyGuide Label
Every new fridge and freezer carries the FTC’s yellow EnergyGuide label, and it is the quickest way to get your own fridge’s number. Under 16 CFR 305.14 it must show [5][6]:
- Estimated yearly electricity use in kWh. This is the number to use. Divide by 365 for kWh a day, or by 8.76 for average watts.
- Estimated yearly energy cost, based on a national average electricity price printed on the label. The label itself says your cost will depend on your utility rates and use.
- A cost range for similar models, showing where this one sits among models of similar size and layout.
- The capacity and configuration the comparison is based on, and the ENERGY STAR logo if the model is certified.
Worked example: a label reading 560 kWh is 560 ÷ 8.76 = about 64 W on average, or 1.53 kWh a day. If the label is gone, look the model up in ENERGY STAR’s list [1]. The rating comes from a standardized lab test [4], so a warm kitchen, frequent door openings or an ice maker push real use higher. To convert between watts and kWh for any appliance, use the watts to kWh calculator.
If all you have is the volts and amps on the rating sticker inside the fridge, volts × amps gives a conservative upper figure, not the running draw. For comparison, the 18–20 cu ft top-freezer models in the service sheet above run at under 1 A [7].
How to Measure Your Own Fridge With a Plug-In Meter
For an older fridge, or one in a garage, a plug-in watt meter gives you the real figure. P3’s Kill A Watt P4400 is the common example: it shows watts, volts, amps and power factor, and counts cumulative kWh and the hours since it was plugged in. It is rated to 15 A and 1,875 W, well above any household fridge [20]. Many public libraries lend these meters for free; in Maine, Efficiency Maine runs a statewide library loan program [21].
- Plug the meter into the wall and the fridge into the meter. Keep using the fridge normally.
- Leave it at least 24 hours, ideally a week, so the count includes defrost cycles and door openings.
- Read the kWh and the elapsed hours. Average watts = kWh ÷ hours × 1,000. For example, 3.6 kWh over 72 hours is 50 W.
- Glance at the live watts while the compressor is humming: that is the running draw.
Don’t expect the meter to show the start-up surge. The P4400 updates its display once a second [20], and a compressor start is over in a fraction of that, so use the starting figures above for surge.
What Size Solar Generator Runs a Fridge and Freezer?
Battery size, not the inverter, decides how long a fridge runs on a power station; every station below clears the start-up surge. The math, with its assumptions:
The 0.85 is our planning allowance for inverter losses, not a measured figure. Average watts come from the ENERGY STAR medians above, so the duty cycle is already built in and we don’t assume one. A station’s own idle draw also uses some battery: BLUETTI quotes standby use as low as 4 W for its FridgePower, and The Solar Lab measured about 16.8 W idle [30][31]. Treat these as best-case hours for a new fridge in a cool kitchen with the door kept shut.
| Load (ENERGY STAR medians) | Average watts / kWh a day | Battery for 24 h | Anker SOLIX C1000 Gen 21,024 Wh / 3,000 W surge | Jackery Explorer 2000 v22,042 Wh / 4,400 W surge | Jackery HomePower 30003,072 Wh / 7,200 W surge |
|---|---|---|---|---|---|
| Top-freezer fridge alone363 kWh a year | ~41 W / 0.99 kWh | ~1,180 Wh | ~21 h | ~42 h | ~63 h |
| French-door with door ice alone715 kWh a year | ~82 W / 1.96 kWh | ~2,310 Wh | ~11 h | ~21 h | ~32 h |
| Top-freezer fridge + chest freezer581 kWh a year | ~66 W / 1.59 kWh | ~1,880 Wh | ~13 h | ~26 h | ~39 h |
| Bottom-freezer fridge + upright freezer977 kWh a year | ~112 W / 2.68 kWh | ~3,150 Wh | ~7.8 h | ~16 h | ~23 h |
| French-door with ice + upright freezer1,153 kWh a year | ~132 W / 3.16 kWh | ~3,720 Wh | ~6.6 h | ~13 h | ~20 h |
Our arithmetic. Station capacities and surge ratings come from our product database, cross-checked against the sources listed. Start check: all three clear Champion’s 2,200 W single-fridge start; for two appliances, the C1000 Gen 2’s 3,000 W covers one start plus a running freezer (2,600 W) but not two simultaneous starts, while the Explorer 2000 v2 (4,400 W) and HomePower 3000 (7,200 W) cover both starting at once. These are estimates, not test results.
The rule of thumb: about 1 kWh of battery per fridge per day, and about 2–4 kWh for a fridge plus a freezer. To recharge from solar between outage days, size panels with the solar size calculator. For UPS takeover, the four-hour food-safety rule and more station options, see can a solar generator run a refrigerator.
One fridge overnight (1 kWh)
Anker SOLIX C1000 Gen 2 · Our score 92/100
1,024 Wh · 2,000 W continuous · 3,000 W surge · UPS 10 ms · 24.9 lb · LiFePO4 [24][25]
Price on Amazon: $469.99
The fastest UPS switchover of the three picks (10 ms, per Anker), so it can sit between the wall and the fridge and take over on its own. By our math it runs a typical ENERGY STAR top-freezer fridge for about 21 hours and a French-door model with door ice for about 11. Its 3,000 W surge rating clears even Champion’s conservative 2,200 W fridge start figure.
Skip it if: You also need to keep a freezer cold, or you have a big French-door fridge and outages that run past one night. One kilowatt-hour is about one day of a small fridge, not a fridge plus a freezer.
Fridge + chest freezer for a day
Jackery Explorer 2000 v2 · Our score 87/100
2,042 Wh · 2,200 W continuous · 4,400 W surge · UPS 20 ms or less · 39.5 lb · LiFePO4 [26][27]
Price on Amazon: $999.00
Twice the battery at 39.5 lb. About 1.7 kWh usable covers a top-freezer fridge plus a chest freezer for about 26 hours, or a French-door fridge with door ice for about 21, by our math. 2,200 W continuous and 4,400 W surge leave room for one compressor starting while the other runs.
Skip it if: You want to recharge fast from solar: it accepts 400 W, the least of the three picks, which is a slow refill for a two-appliance load.
Fridge + upright freezer (3 kWh)
Jackery HomePower 3000 · Our score 87/100
3,072 Wh · 3,600 W continuous · 7,200 W surge · UPS 20 ms or less · 59.5 lb · LiFePO4 [28][29]
The size for a full-size fridge and an upright freezer together: about 2.6 kWh usable is roughly 23 hours of a bottom-freezer fridge plus an upright freezer by our math. Its 3,600 W continuous and 7,200 W surge ratings clear both compressors starting at the same moment, even on Champion’s conservative figures, and it accepts up to 1,000 W of solar.
Skip it if: You need to carry it often (59.5 lb) or want to add batteries later; it cannot be expanded.
Side by side
| Station | Usable energy | Continuous / surge | Top-freezer fridge (~41 W) | Weight | Price | Link |
|---|---|---|---|---|---|---|
| Anker SOLIX C1000 Gen 2 | ~870 Wh | 2,000 / 3,000 W | ~21 h | 24.9 lb | $469.99 | View on Amazon → |
| Jackery Explorer 2000 v2 | ~1,736 Wh | 2,200 / 4,400 W | ~42 h | 39.5 lb | $999.00 | View on Amazon → |
| Jackery HomePower 3000 | ~2,611 Wh | 3,600 / 7,200 W | ~63 h | 59.5 lb | Check price at Amazon → | View on Amazon → |
Dedicated fridge batteries: BLUETTI FridgePower and Jackery FridgeGuard
Two thin batteries are built only to sit beside a fridge and take over when the grid drops. The Bluetti Fridge Power (our score 85/100) has 2,016 Wh, 1,800 W continuous with a 3,600 W surge, an under-10 ms UPS and expansion to 8,064 Wh [30][31]; by our math it runs a median bottom-freezer fridge for ~28 h. The Jackery Fridge Guard (80/100) has 1,024 Wh, 800 W with a 1,600 W peak and a 10 ms-or-less UPS [32][33], about ~21 h on a median top-freezer fridge. Its 1,600 W peak clears Honda’s 1,200 W starting figure for ENERGY STAR fridges but not Champion’s generic 2,200 W, so it suits a newer fridge better than an old one. Details are in our BLUETTI FridgePower review and Jackery FridgeGuard review.
Running a fridge in a van or at camp instead? A 12 V compressor fridge runs straight off a battery’s DC port without inverter losses; our best 12V fridge guide compares them. For everything else you might run during an outage, see the appliance wattage chart, and for cooling loads the air conditioner wattage guide.
Verdict: Plan on 1 kWh a Day per Fridge
A new full-size fridge averages about 40–80 W, or 1–2 kWh a day, draws roughly 80–200 W while its compressor runs and can need up to about 2,200 W for an instant at start-up. Get your own number from the EnergyGuide label or a plug-in meter, then size the battery to the kWh. For one fridge through a night, the Anker SOLIX C1000 Gen 2 (our score 92/100) is enough and switches over on its own. Currently $469.99 on Amazon, it runs a median top-freezer fridge for about 21 hours by our math. For a fridge plus a freezer, step up to the Jackery Explorer 2000 v2 (87/100) for a chest freezer, or the Jackery HomePower 3000 (87/100) for an upright.
Refrigerator Wattage FAQ
How many watts does a refrigerator use?
On average, about 40–80 W for a new full-size fridge: the median ENERGY STAR top-freezer model uses 363 kWh a year (about 41 W) and the median French-door model with door ice uses 715 kWh (about 82 W). While the compressor runs, a modern fridge draws roughly 80–200 W; generator charts allow up to 400 W for an older or unknown fridge.
How many kWh does a refrigerator use per day?
About 1–2 kWh for a full-size fridge: 0.99 kWh for the median ENERGY STAR top-freezer model, 1.48 for a bottom-freezer or French-door model without a door dispenser, 1.76 for a side-by-side and 1.96 for a French-door model with door ice. Divide the kWh on your fridge's yellow EnergyGuide label by 365 for your own figure.
How many watts does a refrigerator need to start?
Generator makers plan on 1,200 W (Honda, for an ENERGY STAR refrigerator or freezer) to 2,200 W (Champion, for a generic refrigerator) for the split second the compressor starts. Inverter (variable-speed) fridges ramp up softly and need far less. To be safe, choose a power station with a surge rating above 2,200 W.
How many watts does a mini fridge use?
The median ENERGY STAR compact fridge uses 246 kWh a year, about 28 W on average or 0.67 kWh a day. While running, two 3.1 cu ft models list 1.0 and 1.3 A at 115 V on their spec sheets, roughly 115–150 W or a little less.
How many watts does a freezer use?
The median ENERGY STAR upright freezer uses 438 kWh a year, about 50 W on average or 1.2 kWh a day. Chest freezers use less: the nine certified full-size chest models range from 201 to 346 kWh a year, a median of 218 (about 25 W). Honda plans freezers like fridges, at 132–192 W running and 1,200 W to start.
What size solar generator do I need to run a refrigerator and freezer?
About 2–4 kWh of battery for a day. Battery Wh for 24 hours = kWh per day × 1,000 ÷ 0.85. A top-freezer fridge plus a chest freezer needs about 1.9 kWh; a bottom-freezer fridge plus an upright freezer about 3.1 kWh; a French-door fridge with door ice plus an upright about 3.7 kWh. The station's surge rating should clear one 2,200 W start plus the other appliance running, about 2,600 W.
Sources
Energy figures come from ENERGY STAR’s public certified-model datasets, which report each model’s DOE-tested annual kWh; label rules from the FTC’s Energy Labeling Rule; running and starting figures from manufacturer spec and service sheets and generator makers’ published charts, as cited. Medians, average watts, battery sizes and runtimes are our arithmetic on those figures. Station specs come from our product database, cross-checked against the listings below. Nothing here was measured by us. Last reviewed November 16, 2026.
- ENERGY STAR Certified Residential Refrigerators dataset (4,942 models, downloaded Nov 15, 2026): annual kWh, type, volume and federal-standard kWh by model
- ENERGY STAR Certified Residential Freezers dataset (680 models, downloaded Nov 15, 2026)
- ENERGY STAR, Refrigerators: certified models about 9% more efficient than the federal minimum; top-freezer models tend to use the least energy
- 10 CFR Part 430, Subpart B, Appendix A: DOE test procedure for refrigerator annual energy use in kWh per year (Cornell LII copy of the eCFR)
- 16 CFR 305.14: required content of the EnergyGuide label for refrigerators and freezers (Cornell LII copy of the eCFR)
- FTC Consumer Advice, Shopping for home appliances? Use the EnergyGuide label
- Service data sheet A16319701, automatic-defrost top-mount R600a refrigerators (CD/SD 18 and SD 20 cu ft): running watts, running amps, run time at 70 and 90 °F, 178 W defrost heater (iFixit copy)
- GE Appliances, Refrigerator: normal cycle times (compressors designed to run 80–90% of the time; defrost about 35 minutes)
- Frigidaire, Why does my refrigerator run most of the time? (variable-speed compressors run continuously except during defrost; warm locations raise run time)
- Honda Power Equipment, Generator wattage estimation guide: refrigerator or freezer (ENERGY STAR) 132–192 W running, 1,200 W starting
- Champion Power Equipment, Choosing a generator wattage chart: refrigerator 400 W running, 2,200 W starting; add the highest single starting load to total running watts
- Embraco EM X20CLC compressor technical data (1/12 hp, 115–127 V 60 Hz, R-600a): LRA 3.70 A, full-load 0.55 A, 49 W at the ASHRAE check point
- MicroFridge (Danby) 3.1MF7-7A1 spec sheet: 3.1 cu ft refrigerator, 115 V, start-up 4.5 A, operating 1.3 A, 195 kWh per year
- Hisense LMT33M6AVE spec sheet: 3.1 cu ft compact refrigerator, 115 V / 60 Hz / 1.0 A, 321 kWh per year
- Embraco, Variable speed compressors (on-off units need abrupt power at start; variable-speed units start slow and ramp up over a few minutes)
- ACHR News, Variable-speed compressors vs on-off compressors (soft start dramatically reduces motor starting current)
- Danfoss, Variable-speed (inverter) technology: soft start with near-zero inrush
- GE Appliances, Top-freezer refrigerators: garage-ready models (38–110 °F; non-garage-ready models not recommended below 60 °F)
- Whirlpool, How garage-ready refrigerators work (cold air can let a standard unit’s freezer warm and thaw; Garage Mode for 38–55 °F)
- P3 International, P4400 Kill A Watt operation manual: watts, VA, power factor, cumulative kWh and elapsed hours; 0–15 A, 0–1,875 W; 1-second display update
- Efficiency Maine, Electricity monitor loaners (free loans through participating public libraries)
- U.S. FDA, Food and water safety during power outages and floods (refrigerator about 4 hours unopened; full freezer about 48 hours, half full 24)
- USDA FSIS, Avoid foodborne illness during temporary power outages
- B&H Photo spec listing, Anker SOLIX C1000 Gen 2 (1,024 Wh, 2,000 W continuous, 3,000 W surge)
- Anker SOLIX support, C1000 Gen 2 UPS ports and switchover time (10 ms)
- Jackery, Explorer 2000 v2 product page (2,042 Wh LiFePO4, 2,200 W output, 4,400 W surge, UPS 20 ms or less)
- The Solar Lab, Jackery Explorer 2000 v2 review
- Jackery, HomePower 3000 product page (3,072 Wh, 3,600 W, 7,200 W surge)
- The Solar Lab, Jackery HomePower 3000 review
- BLUETTI, FridgePower product page (2,016 Wh, under-10 ms UPS, expandable to 8,064 Wh)
- The Solar Lab, BLUETTI FridgePower review (idle draw about 16.8 W in its test)
- Jackery, FridgeGuard product page (1,024 Wh, 800 W, 1,600 W peak, 10 ms or less UPS)
- Digital Trends, Jackery’s FridgeGuard is the slimmest fridge backup battery