ENERGY STAR + DOE Data · Updated November 2026
How Many Watts Does a Freezer Use? Chest, Upright and Compact
The short answers
- Chest freezer
- About 25 W on average, or 0.60 kWh a day: the median certified full-size chest model uses 218 kWh a year [1].
- Upright freezer
- About 50 W on average, or 1.20 kWh a day (median 438 kWh a year), roughly double a chest [1][2].
- While the compressor runs
- About 60–145 W for a chest freezer on two service data sheets; generator charts allow 132–192 W (Honda) up to 700 W (Lowe’s) [5][6][7][8].
- Starting watts
- 1,200 W (Honda) to about 2,900 W (Lowe’s 700 running + 2,200 starting) for a split second [7][8].
Jump to watts by freezer type, starting watts or what size solar generator runs a chest freezer.
As an Amazon Associate, SolarGenAdvisor earns from qualifying purchases made through links on this page, at no additional cost to you.
Freezer Watts and kWh by Type
A freezer runs around the clock but its compressor cycles, so the useful numbers are its average watts and kWh per day. Every freezer sold in the U.S. is rated in kWh per year under DOE’s freezer test procedure [4], and ENERGY STAR publishes that rating for every certified model. We downloaded its list of 680 certified freezers on November 16, 2026 and took the median for each type [1]. Average watts are annual kWh ÷ 8,760 hours.
| Type | kWh / year (ENERGY STAR median) | Average watts | kWh / day | Most models fall between | At the federal maximum |
|---|---|---|---|---|---|
| Chest freezer (full-size)9 models · median 10.6 cu ft · All manual defrost | 218 kWh | ~25 W | 0.60 | 201–346 kWh~23–39 W average; lowest–highest of all 9 models | 244 kWh~28 W average |
| Compact chest freezer40 models · median 5.1 cu ft · Manual defrost | 196 kWh | ~22 W | 0.54 | 172–225 kWh~20–26 W average | 219 kWh~25 W average |
| Upright freezer (full-size)509 models · median 15.5 cu ft · 505 of 509 frost-free | 438 kWh | ~50 W | 1.20 | 384–528 kWh~44–60 W average | 494 kWh~56 W average |
| Compact upright, manual defrost93 models · median 3.1 cu ft · Manual defrost | 244 kWh | ~28 W | 0.67 | 215–296 kWh~25–34 W average | 273 kWh~31 W average |
| Compact upright, frost-free29 models · median 4.6 cu ft · Automatic defrost | 369 kWh | ~42 W | 1.01 | 295–390 kWh~34–45 W average | 433 kWh~49 W average |
Our arithmetic on the ENERGY STAR dataset [1]. “Most models” is the 10th to 90th percentile; for full-size chest freezers, only nine models were certified, too few for percentiles, so their range is the lowest and highest of those nine, 201–346 kWh (9–22 cu ft). Compact rows follow DOE’s compact product classes. The last column is the median of the federal-standard kWh ENERGY STAR lists for the same models, roughly what a model that only just meets the federal limit would use; ENERGY STAR says certified freezers are at least 10% more efficient than that minimum [2].
Why a chest freezer uses about half as much
Two reasons, both in ENERGY STAR’s own guidance. A chest opens from the top, so less cold air escapes, and manual-defrost freezers use about half the energy of automatic-defrost models [2]. All nine certified full-size chest models are manual defrost, while 505 of the 509 certified uprights are frost-free (automatic defrost) [1]. The compact rows show the defrost effect on its own: compact uprights use a median 244 kWh a year with manual defrost and 369 frost-free. Built-in uprights use more than freestanding ones (median 493 against 435 kWh), and the full-size upright row includes both. To keep a manual-defrost chest at its rating, ENERGY STAR says not to let frost build up more than a quarter inch [2].
How Many Watts Does a Chest Freezer Use?
On average, about 25 W for a full-size chest freezer and about 22 W for a compact one, or 0.60 and 0.54 kWh a day [1]. While its compressor is running, a chest freezer draws more. Few makers publish running watts, but service data sheets do. Two sheets for chest freezers list 60–140 W in a 70 °F room, with the compressor running 20–40% of the time, and 70–145 W at 90 °F, running 30–50% of the time [5][6]. That agrees with the label data: about 100 W running a quarter of the day is 0.60 kWh, the same as the median certified chest model (our arithmetic).
Generator makers’ planning charts run higher, because they have to cover every freezer. Honda lists an ENERGY STAR refrigerator or freezer at 132–192 W running [7], and Lowe’s chart lists a refrigerator/freezer at 700 W [8]. Champion’s chart has no freezer row; its refrigerator row is 400 W [9]. Use the chart figures for an old or unknown freezer, and the label or a meter (both below) for a real number.
Size matters less than you would think
The nine certified full-size chest models run from 9.0 to 21.7 cu ft, and the largest 21.7 cu ft models use 346 kWh a year, about 39 W on average. The 10 cu ft models use 211–218 kWh [1]. That means roughly twice the space for about 60% more energy. A compact 5 cu ft chest saves less than its size suggests: its median 196 kWh is only about 10% below the median full-size chest.
These are new, certified models, which ENERGY STAR says are at least 10% more efficient than the federal minimum [2]; the federal-maximum column above shows what a model that only just meets today’s limit would use. An older freezer can differ from both, so read its label or measure it.
Starting Watts: Freezer Compressor Surge
A conventional freezer compressor is switched straight on. For a fraction of a second, before it is up to speed, it draws its locked-rotor current, several times its running current. Embraco’s datasheet for a small 1/12 hp, 115 V household compressor shows the scale: 3.70 A locked-rotor against 0.55 A at full load, about 6.7× [10]. Whole-appliance start figures are lower because the start is so brief.
Generator makers publish planning figures, not measurements of any one freezer: 1,200 W starting for an ENERGY STAR refrigerator or freezer (Honda), and 700 W running plus 2,200 W additional starting for a refrigerator/freezer (Lowe’s) [7][8]. Both charts say to add the highest single starting figure to the running watts of everything else [8][9]. We use the Lowe’s figures in the station checks below because they are the most conservative:
- One freezer: 700 + 2,200 = 2,900 W of surge.
- Freezer plus fridge: both running plus one start, 700 + 700 + 2,200 = 3,600 W. We also check the case where both compressors start at the same moment, 5,800 W.
- Continuous output: easy. Even two appliances at the chart’s 700 W each is 1,400 W.
A plug-in meter can’t show this surge (see below), so check a station’s published surge rating against these figures rather than against anything you measure.
Chest Freezers in a Garage: Heat and Cold
ENERGY STAR’s figures come from a lab test in a controlled room [4]. A garage changes them in both directions.
A hot garage raises the kWh
The two chest-freezer service sheets show the effect directly. In a 90 °F room, compressor run time rises from 20–40% to 30–50%, and running watts creep up from 60–140 to 70–145 W [5][6]. That is roughly 1.25–1.5× the compressor time (our arithmetic for those models). For a chest freezer in a hot garage, budget about a third above its label kWh in summer, which is also how our freezer backup sizing guide handles garage units.
A cold garage is a design question
Makers set different cold limits, so check yours. GE says its upright and chest freezers are proven to perform in rooms from 0 to 110 °F, and its installation guide says not to place a freezer where it will fall below 0 °F [11][12]. Whirlpool tells owners of its convertible chest freezer to avoid locations below 40 °F or above 110 °F [13]. ENERGY STAR’s advice is to keep a freezer indoors, such as in a basement, unless you live in a mild climate, because extreme temperatures strain the compressor [2]. A freezer listed as “garage-ready” states its own ambient range; for any other, the owner’s manual is the authority.
How to Read the Freezer EnergyGuide Label
Every new freezer carries the FTC’s yellow EnergyGuide label, and it is the quickest way to get your own freezer’s number. Under 16 CFR 305.14 it must show [14][15]:
- Estimated yearly electricity use in kWh. This is the number to use. Divide by 365 for kWh a day, or by 8.76 for average watts.
- Estimated yearly energy cost, based on a national average electricity price printed on the label. Your cost depends on your own rate.
- A cost range for similar models, showing where this one sits among freezers of similar size and type.
- The capacity and type the comparison is based on (for example, chest with manual defrost), and the ENERGY STAR logo if the model is certified.
Worked example: a chest freezer label reading 277 kWh, as on a certified 15.7 cu ft model, is 277 ÷ 8.76 = about 32 W on average, or 0.76 kWh a day [1]. If the label is gone, look the model number up in ENERGY STAR’s list. The rating comes from a standardized test [4], so a hot garage, frequent opening or heavy frost pushes real use higher. To convert between watts and kWh for any appliance, use the watts to kWh calculator.
If all you have is the volts and amps on the rating plate, volts × amps gives a conservative upper figure, not the running draw. For comparison, the service sheets above put chest freezers at about 60–145 W while running [5][6].
How to Measure Your Freezer With a Plug-In Meter
For an older freezer, or one in a garage, a plug-in watt meter gives you the real figure. P3’s Kill A Watt P4400 is the common example: it shows watts, volts, amps and power factor, and counts cumulative kWh and the hours since it was plugged in. It is rated to 15 A and 1,875 W, well above any household freezer [16]. Many public libraries lend these meters for free; in Maine, Efficiency Maine runs a statewide library loan program [17].
- Plug the meter into the wall and the freezer into the meter. Keep using the freezer normally.
- Leave it at least 24 hours, ideally a week, so the count covers normal openings and, on a frost-free upright, defrost cycles.
- Read the kWh and the elapsed hours. Average watts = kWh ÷ hours × 1,000. For example, 1.8 kWh over 72 hours is 25 W, a typical chest freezer.
- Glance at the live watts while the compressor is humming: that is the running draw.
Don’t expect the meter to show the start-up surge. The P4400 updates its display once a second [16], and a compressor start is over in a fraction of that, so use the starting figures above for surge. In a garage, measure in summer if you can; that is the worst case for battery sizing.
What Size Solar Generator for a Chest Freezer?
Battery size, not the inverter, decides how long a freezer runs on a power station; every station below clears the start-up surge. This is the short version. Our solar generator for a freezer guide covers multi-day outages, why a full freezer holds out longer, and more station options.
The 0.85 is our planning allowance for inverter losses, not a measured figure. Average watts come from the ENERGY STAR medians above, so the duty cycle is already built in. The station’s own idle draw also uses some battery, so treat these as best-case hours for a closed freezer in a cool room.
| Load (ENERGY STAR medians) | Average watts / kWh a day | Battery for 24 h | Anker SOLIX C1000 Gen 21,024 Wh / 3,000 W surge | Jackery Explorer 2000 v22,042 Wh / 4,400 W surge | Jackery HomePower 30003,072 Wh / 7,200 W surge |
|---|---|---|---|---|---|
| Chest freezer alone218 kWh a year | ~25 W / 0.60 kWh | ~710 Wh | ~35 h | ~70 h | ~105 h |
| Compact chest freezer alone196 kWh a year | ~22 W / 0.54 kWh | ~640 Wh | ~39 h | ~78 h | ~117 h |
| Upright freezer alone438 kWh a year | ~50 W / 1.20 kWh | ~1,420 Wh | ~17 h | ~35 h | ~52 h |
| Top-freezer fridge + chest freezer581 kWh a year | ~66 W / 1.59 kWh | ~1,880 Wh | ~13 h | ~26 h | ~39 h |
| Bottom-freezer fridge + upright freezer977 kWh a year | ~112 W / 2.68 kWh | ~3,150 Wh | ~7.8 h | ~16 h | ~23 h |
Our arithmetic. Fridge figures are the ENERGY STAR medians from our refrigerator page (top-freezer 363, bottom-freezer 539 kWh a year) [3]. Station capacities and surge ratings come from our product database, cross-checked against the sources listed. Start check on the Lowe’s figures: all three clear one freezer starting (2,900 W); for a fridge plus a freezer, the Explorer 2000 v2 (4,400 W) and HomePower 3000 (7,200 W) cover one start with the other running (3,600 W) and only the HomePower 3000 covers both starting at once (5,800 W). These are estimates, not test results.
One Chest Freezer (1 kWh)
Anker SOLIX C1000 Gen 2 · Our score 92/100
1,024 Wh · 2,000 W continuous · 3,000 W surge · UPS 10 ms · 24.9 lb · LiFePO4 [20][21]
Price on Amazon: $469.99
The fastest UPS switchover of the three (10 ms, per Anker), so it can sit between the wall and the freezer and take over on its own. By our math it runs a median ENERGY STAR chest freezer for ~35 h and an upright for ~17 h. Its 3,000 W surge rating clears even the most conservative published single-freezer start (2,900 W on the Lowe’s chart).
Skip it if: You also need to keep a fridge running, or you want more than a night and a day on an upright. A fridge plus a freezer needs about twice this battery.
Fridge + Chest Freezer (2 kWh)
Jackery Explorer 2000 v2 · Our score 87/100
2,042 Wh · 2,200 W continuous · 4,400 W surge · UPS 20 ms or less · 39.5 lb · LiFePO4 [22][23]
Price on Amazon: $999.00
Twice the battery at 39.5 lb: ~70 h on a chest freezer alone, or ~26 h on a top-freezer fridge plus a chest freezer, by our math. Its 4,400 W surge covers one compressor starting while the other runs, even on the Lowe’s figures (3,600 W).
Skip it if: You want to recharge quickly from solar: it accepts 400 W, the least of the three, which is a slow refill for a two-appliance load.
Fridge + Upright Freezer (3 kWh)
Jackery HomePower 3000 · Our score 87/100
3,072 Wh · 3,600 W continuous · 7,200 W surge · UPS 20 ms or less · 59.5 lb · LiFePO4 [24][25]
The size for a full-size fridge plus an upright freezer: ~23 h on a bottom-freezer fridge and an upright by our math. Its 7,200 W surge clears both compressors starting at the same moment, even on the Lowe’s figures (5,800 W), and it accepts up to 1,000 W of solar.
Skip it if: You need to carry it often (59.5 lb) or want to add batteries later; it cannot be expanded.
Side by side
| Station | Usable energy | Continuous / surge | Chest freezer (~25 W) | Upright freezer (~50 W) | Price | Link |
|---|---|---|---|---|---|---|
| Anker SOLIX C1000 Gen 2 | ~870 Wh | 2,000 / 3,000 W | ~35 h | ~17 h | $469.99 | View on Amazon → |
| Jackery Explorer 2000 v2 | ~1,736 Wh | 2,200 / 4,400 W | ~70 h | ~35 h | $999.00 | View on Amazon → |
| Jackery HomePower 3000 | ~2,611 Wh | 3,600 / 7,200 W | ~105 h | ~52 h | Check price at Amazon → | View on Amazon → |
Backing up the kitchen fridge too? Our guide to how many watts a refrigerator uses has the same figures for every fridge type, and can a solar generator run a refrigerator covers UPS takeover and the dedicated fridge batteries. For everything else you might run in an outage, see the appliance wattage chart. To recharge from solar between outage days, size panels with the solar size calculator.
Verdict: A Chest Freezer Needs About 0.6 kWh a Day
A new chest freezer averages about 25 W, or 0.6 kWh a day, and an upright about 50 W, or 1.2 kWh. Either draws roughly 60–145 W while its compressor runs and can need up to about 2,900 W for an instant at start-up on the most conservative chart. Get your own number from the EnergyGuide label or a plug-in meter, add about a third for a hot garage, then size the battery to the kWh. For one chest freezer, the Anker SOLIX C1000 Gen 2 (our score 92/100) is enough and switches over on its own. Currently $469.99 on Amazon, it runs a median chest freezer for ~35 h by our math. For a fridge plus a freezer, step up to the Jackery Explorer 2000 v2 (87/100) with a chest freezer, or the Jackery HomePower 3000 (87/100) with an upright.
Food safety if the battery runs out
The FDA says a full freezer holds its temperature for about 48 hours without power, and a half-full one about 24, if the door stays closed [18][19]. Keep the lid shut and an appliance thermometer inside, and check our guide to how long food lasts without power for what you can refreeze afterward.
Freezer Wattage FAQ
How many watts does a freezer use?
On average, about 25 W for a new chest freezer and about 50 W for an upright: the median ENERGY STAR chest model uses 218 kWh a year and the median upright 438 kWh. While the compressor runs, a chest freezer draws roughly 60–145 W on manufacturer service sheets; generator charts allow 132–192 W (Honda) up to 700 W (Lowe's) for an older or unknown freezer.
How many watts does a chest freezer use per day?
About 0.6 kWh a day, or 600 watt-hours, for the median ENERGY STAR full-size chest freezer (218 kWh a year, about 25 W on average). The nine certified full-size chest models range from 0.55 to 0.95 kWh a day; a compact chest freezer uses a median 0.54 kWh. Divide the kWh on your freezer's yellow EnergyGuide label by 365 for your own figure.
How many watts does a freezer need to start?
Generator makers plan on 1,200 W (Honda, for an ENERGY STAR refrigerator or freezer) up to about 2,900 W (Lowe's chart: 700 W running plus 2,200 W additional starting) for the split second the compressor starts. To be safe, choose a power station with a surge rating above 2,900 W, or above 3,600 W if it also runs a fridge.
Does a chest freezer use less electricity than an upright?
Yes, about half. The median certified full-size chest freezer uses 218 kWh a year against 438 kWh for the median upright. ENERGY STAR says chest models lose less cold air because they open from the top, and manual-defrost models use about half the energy of automatic-defrost ones; all certified full-size chest models are manual defrost, while nearly all uprights are frost-free.
Can a chest freezer go in a cold garage?
It depends on the model's rated room temperature range. GE rates its chest and upright freezers for rooms from 0 to 110 °F, while Whirlpool tells owners of its convertible chest freezer to avoid locations below 40 °F. Check the owner's manual. In a hot garage, expect more energy use: service sheets show compressor run time rising from 20–40% at 70 °F to 30–50% at 90 °F.
What size solar generator do I need for a chest freezer and a fridge?
About 700 Wh of battery runs a median chest freezer for a day, and about 1.9 kWh runs a top-freezer fridge plus a chest freezer. Battery Wh for 24 hours = kWh per day × 1,000 ÷ 0.85. A bottom-freezer fridge plus an upright freezer needs about 3.2 kWh. The station's surge rating should clear about 2,900 W for one freezer, or 3,600 W for a fridge and freezer together.
Sources
Energy figures come from ENERGY STAR’s public certified-model dataset, which reports each model’s DOE-tested annual kWh; label rules from the FTC’s Energy Labeling Rule; running and starting figures from manufacturer service sheets and generator makers’ and retailers’ published charts, as cited. Medians, average watts, battery sizes and runtimes are our arithmetic on those figures. Station specs come from our product database, cross-checked against the listings below. Nothing here was measured by us. Last reviewed November 16, 2026.
- ENERGY STAR Certified Residential Freezers dataset (680 models, downloaded Nov 16, 2026): annual kWh, type, product class, defrost type, volume and federal-standard kWh by model
- ENERGY STAR, Freezers: certified models at least 10% more efficient than the federal minimum; chest models usually more efficient; manual-defrost models use half the energy of automatic-defrost models; keep frost under 1/4 inch
- ENERGY STAR Certified Residential Refrigerators dataset (median annual kWh by type, as used on our refrigerator wattage page)
- 10 CFR Part 430, Subpart B, Appendix B: DOE uniform test method for freezer annual energy use in kWh per year (Cornell LII copy of the eCFR)
- Service data sheet 297010500/297010501, chest freezer: 20–40% running time and 65–140 W (last third of cycle) at 70 °F; 30–50% and 70–145 W at 90 °F (AJ Madison copy)
- Service data sheet A02384402, chest freezer (WWFC18M4RC document): 20–40% running time and 60–130 W at 70 °F; 30–50% and 70–145 W at 90 °F (AJ Madison copy)
- Honda Power Equipment, Generator wattage estimation guide: refrigerator or freezer (ENERGY STAR) 132–192 W running, 1,200 W starting
- Lowe’s, Portable generator wattage chart (04/2017): refrigerator/freezer 700 W running, 2,200 W additional starting; add the highest starting watts to total running watts
- Champion Power Equipment, Choosing a generator wattage chart: refrigerator 400 W running, 2,200 W starting (no separate freezer row)
- Embraco EM X20CLC compressor technical data (1/12 hp, 115–127 V 60 Hz): LRA 3.70 A, full-load 0.55 A
- GE Appliances, Freezers: GE upright and chest freezers are proven to perform at room temperatures from 0 to 110 °F
- GE Appliances, Upright & chest freezer installation and location: surrounding temperature not above 110 °F or below 0 °F; air clearances
- Whirlpool, Too warm: convertible chest freezer (avoid locations below 40 °F or above 110 °F)
- 16 CFR 305.14: required content of the EnergyGuide label for refrigerators and freezers (Cornell LII copy of the eCFR)
- FTC Consumer Advice, Shopping for home appliances? Use the EnergyGuide label
- P3 International, P4400 Kill A Watt operation manual: watts, VA, power factor, cumulative kWh and elapsed hours; 0–15 A, 0–1,875 W; 1-second display update
- Efficiency Maine, Electricity monitor loaners (free loans through participating public libraries)
- U.S. FDA, Food and water safety during power outages and floods (full freezer about 48 hours, half full about 24, door closed)
- USDA FSIS, Avoid foodborne illness during temporary power outages
- B&H Photo spec listing, Anker SOLIX C1000 Gen 2 (1,024 Wh, 2,000 W continuous, 3,000 W surge)
- Anker SOLIX support, C1000 Gen 2 UPS ports and switchover time (10 ms)
- Jackery, Explorer 2000 v2 product page (2,042 Wh LiFePO4, 2,200 W output, 4,400 W surge, UPS 20 ms or less)
- The Solar Lab, Jackery Explorer 2000 v2 review
- Jackery, HomePower 3000 product page (3,072 Wh, 3,600 W, 7,200 W surge)
- The Solar Lab, Jackery HomePower 3000 review