| C300 / C300 DC |
1 × XT-60, 11–28V, 8.2A, 100W |
1 × PS100 |
25.9V < 28V; 4.86A < 8.2A. The margin is thin: about 28.5V on a freezing morning. The PS200 and PS400 (57.6V) are over the limit, and Anker’s listing says they are not compatible. Two PS100 in series = 51.8V, also over. |
| C800 / C800 Plus |
1 × XT-60, 11–60V, 10A, 300W |
1 × PS400, or 2 × PS200 in parallel |
PS400: 57.6V < 60V, 8.75A < 10A; 400W of panel on a 300W cap gives headroom in average sun. 2 × PS200 in parallel: 8.76A. Two PS100 in series also work (51.8V, 4.86A, 200W). |
| C1000 Gen 2 |
1 × XT-60i, 11–28V at 8.2A or 29–60V at 14.5A, 600W |
3 × PS200 in parallel (600W) |
3 × 4.38A = 13.1A < 14.5A at 48V ≈ 600W. 2 × PS400 in parallel (17.5A) also work, but the station limits the current and caps at 600W, so the extra panel area mostly helps in weak sun. One PS100 runs in the low band (4.63A, 100W). |
| C1000 (first generation) |
1 × XT-60, 11–32V at 10A or 32–60V at 12.5A, 600W |
3 × PS200 in parallel |
13.1A is slightly over the 12.5A limit, so the station clips the current at about 600W (12.5A × 48V). Never two 48V panels in series: 115.2V. |
| S2000 |
1 input, 11–60V, 400W |
1 × PS400, or 2 × PS200 in parallel |
One 57.6V panel per string. 2 × PS200 in parallel = 8.76A, inside the 12.5A upper-band limit retailers list. |
| C2000 Gen 2 |
1 × XT-60, 11–60V, 17A, 800W |
2 × PS400 in parallel (800W) |
2 × 8.75A = 17.5A, about at the 17A limit; 2 × 8.33A at 48V ≈ 800W. Four PS200 in parallel give the same 800W at 42.4 lb against 43.8 lb. |
| F2000 (PowerHouse 767) |
XT-60, 11–32V at 10A or 32–60V at 20A, 1,000W total |
2 × PS400 in parallel (800W) |
17.5A < 20A. A third PS400 in parallel (26.3A) is clipped at 20A, about 960W, so it adds little. Series is out: 115.2V. |
| F3000 |
High-voltage: 11–165V, 17A, 1,600W. Low-voltage: 11–60V, 17A, 800W |
High-voltage: 4 × PS400 (2 in series, 2 strings in parallel). Low-voltage: 2 × PS400 in parallel |
2 in series = 115.2V (about 127V cold) < 165V; 3 in series = 172.8V, over. Two strings = 17.5A at the 17A cap. Total 6 × PS400 = 2,400W, the station’s solar maximum. |
| F3800 |
2 × XT-60, each 11–60V, 25–27A above 15–32V (by firmware), 1,200W |
3 × PS400 in parallel on each input (2,400W) |
3 × 8.33A = 25A at 48V = 1,200W per input. Series is out on a 60V port. Anker’s comparison table gives 25A above 32V on firmware 1.7.8 or earlier and 27A above 15V on 2.1.1 or later. |
| F3800 Plus |
2 inputs, each 11–165V, 17A, 1,600W (3,200W total) |
4 × PS400 per input, 2S2P (8 panels, 3,200W) |
Anker’s design guide shows exactly this 2S2P layout with its 400W portable panels. 2 × 57.6V = 115.2V < 165V. Anker says straight parallel is not recommended, because two panels’ current exceeds 17A. |